Setting FIRST arm to operate as MASTER arm:
1. The MASTER arm should be at the fully retracted position
at this time.
2. Set DIP switch #1:
OFF: pull to open
ON: push to open
3. Set DIP switch #2 and #3 (MODE 1 and MODE 2) to the desire sequence:
DIP #2 DIP #3 Dual Mode Sequence
OFF OFF Single gate mode.
ON OFF MASTER opens 1st, SLAVE opens 2 seconds later.
SLAVE closes 1st, MASTER closes 4 seconds later
OFF ON MASTER opens 1st, SLAVE opens 2 seconds later.
SLAVE closes 1st, MASTER closes 8 seconds later
ON ON MASTER and SLAVE simultaneously open and close.
4. DIP switch #4: (See main manual for additional details)
OFF: Pulse output at ‘AUX OUT’ terminal when gate is opening.
ON: Continuous output at ‘AUX OUT’ terminal when gate is moving.
Gate Operator in the
RERACTED POSITION
CONNECTING THE 45’ COMMUNICATION CABLE:
3
1. Plug the communication cable into the ‘LINK’ terminals of the opener control boards.