Step 2: Strip the wires back 3/16” and attach the wires to the terminal block marked OUT COM on
the keypad control board as shown in (FIG. 7) making sure to keep track of polarity. Connect
the other end to the opener’s control board as shown in Control Board Connections section
below.
NOTE: For a hard-wired application the 318 MHz RF transmitter is automatically disabled.
Step 3: With the power to the opener turned OFF. Remove opener
control board cover and feed enough of the low voltage keypad
wire through a strain relief to reach the gate opener control board
terminals.
Step 4: Attach the wires from the keypad to the opener control board
terminal blocks as shown below. (FIG. 9)
Step 5: Replace the control board cover and turn the power switch
ON. Put the batteries back into the keypad. (FIG. 2) Test the
keypad by entering to open gate.
Step 6: Program new “Personal Master Code” and any additional entry codes
(for a total of 25 entry codes) (if desired). See Program the Keypad on page 5.
Step 7: Slide the keypad into the cover and secure with the small screws provided. (FIG. 8)
OUT COM
Hard-wire from Gate Opener
#
1
#
2
1
2
ABC
3
DEF
4
GHI
5
JKL
6
MNO
7
PRS
8
TUV
9
WXY
0
Connect #1 wire from the
OUT terminal on the keypad
to the CYCLE terminal on the
opener control board.
Connect #2 wire
from the COM terminal on the
keypad to COM terminal on
the opener control board.
#2
POWER
CHGR
CHGR
EDGE
CYCLE
EXIT
SAFETY
COM
COM
LOCK+
LOCK -
#1
Mighty Mule 200 Control Board
Control Board Connection Examples
NOTE: If your control board doesn’t look like any of these diagrams, please refer to the opener’s instruction manual to locate
the control board input.
RECR
GRN
BLK
RED
EXIT
SAFETY
EDGE
CYCLE
COMMON
LINK
Mighty Mule 350 Control Board
Connect #1 wire from the
OUT terminal on the keypad
to CYCLE terminal on the
gate opener control board.
Connect #2 wire from the COM
terminal on the keypad to the
COMMMON terminal on the gate
opener control board.
#1
#2
RECEIVER
ALM
GTO RCVR.
COM
GRN
BLK
RED
CYCLE
SAFETY
EXIT
SHADOW
OPEN
EDGE
COM
CONTROL INPUTS
CLOSE
EDGE
Connect the #1 wire from
the OUT terminal on the keypad to
the CYCLE terminal on the opener
control board.
Connect the #2 wire from the
COM terminal on the keypad
to one of the COM terminals
on the opener control board.
#1
#2
GEN-3 (Blue) Control Boards
GTO/PRO GP-SL100 and GP-SW100
Control Boards
COM
COM
COM
GTO Inc.
SX4000 L
CYCLE
SAFETY
OPEN EDGE
RUN 2
OPEN
CLOSE
STOP
COM
COM
COM
SHADOW
LOOP
Connect the #1 wire from
the OUT terminal on the
keypad to the CYCLE
terminal on the opener
control board.
Connect the #2 wire from the
COM terminal on the keypad
to one of the COM terminals
on the opener control board.
#1
#2
VAR5
K1
PF1
K2
BATT +
K3
K4
VAR4
VAR3
VAR2
VAR1
PWR.
SFTY.
EXIT
CYCLE
EDGE
SENSOR
COMMON
LOCK+
LOCK–
WHT
GRN
RED
BLK
WHT
GRN
SECOND OPR.FIRST OPR.
RED
BLK
14 VAC
OR
SOLAR
ON
ALARM ACCESSORY RCVR
SEQ1
SEQ2
LEARN
BLU
ORG
WHT
GRN
R B G
Connect #1 wire from the
OUT
terminal on the keypad
to the WHT terminal on the
opener control board.
Connect #2 wire
from the COM terminal on the
keypad to GRN terminal on
the opener control board.
PRO-1000, PRO-SL1000 and Old Mighty Mule
Control Boards
#1
#2
Wired Installation of the Keypad
IMPORTANT: Remove the batteries from the keypad. The keypad will not work properly if
batteries are not first removed.
Step 1: Turn the gate opener’s power switch OFF. Run wire through PVC pipe between the opener
control board to protect the wire.
Remove the small rectangular knock-out on the back of the keypad cover and pull the wire into the
cover. Then mount the cover to the post using the screws provided. (FIG. 6)
Knock-out
FIG. 6
FIG. 7
FIG. 8
FIG. 9
1 2 3 4
Vue de la page 3
1 2 3 4 5 6 7 8